Extraction

Page  of 1
Sort
View
Show
KIMAX SOXHLET TYPE...
Kimble

KIMAX SOXHLET TYPE EXTRACTORS

With Standard Taper Joints Complete with Allihn condenser with joint at bottom, Soxhlet extraction tube with top and bottom joint and flat-bottom flask Available in small, medium and large capacities Small Extractor with 125 mL flask (4406E10, E16, E22) Extraction chamber 30 mm i.d. x 95…

PYREX® Extractors...
Corning

PYREX® Extractors With Standard Taper Joints

Condensers have water-jacketed Standard Taper inner joint. Complete with condenser, flask and extraction tube. The low thermal expansion rate means that the PYREX brand extractors can be routinely used in applications requiring protracted heating at temperatures as high as 230°C. The inherent…

Cellulose Extraction...
GE Healthcare

Cellulose Extraction Thimbles

Mechanically strong with excellent retentivity Fits most commercially available Soxhlet extractors All thimbles packaged 25 per box Single thickness thimbles are approximately 1 mm thick; double thickness thimbles are approximately 2 mm thick

EMEA Heating Mantles...
Electrothermal (Bibby Scientific US)

EMEA Heating Mantles For Soxhlet Extraction

Incorporates a stirring module that allows the solution to be stirred and heated at the same time Three positions for 100, 250, 500 or 1,000 mL flasks Designed to maximize safety Separate heating controls for each position Temperature range to 450°C Stirring speed: 50 to 1,000 rpm Solid…

Vaccuum Manifolds...
Agilent Technologies

Vaccuum Manifolds And Accessories

Agilent manifolds and accessories complement the quality of AccuBOND II sorbents. Flexible configurations and availability as complete assemblies or individual components mean that the user has the necessary capability at any stage from method development to high throughput operation. Vacuum…

Extraction System
Avantor – J.T.Baker®

Extraction System

The BAKER SPE-12G is compatible with a large variety of glassware, including standard test tubes, volumetric flasks and autosampler vials. Samples are aspirated through disposable, prepacked extraction columns which selectively remove compounds from solution. Extracted compounds are then eluted…

Vacuum Manifolds For...
Agilent Technologies

Vacuum Manifolds For 96 Well Plates

These stations allow configurations that are usable for both method development and routine testing. Flexible 96-well trays are designed for easy configuration with the selection of cartridges you need for method development. Fill a row, column, or other arrangement, and cap the rest. Fixed 96-well…

Norton Alundum...
Saint Gobain

Norton Alundum Extraction Thimbles

For the extraction of soaps, fats, foods, rubber, etc. by both organic and inorganic solvents These thimbles offer the advantages of being rapid, durable and readily cleaned by ignition 4395L15 thimble is used in asphalt extraction apparatus for ASTM Standard D 367; AASHTO T-81; and Barrett tests…

PYREX Soxhlet...
Corning

PYREX Soxhlet Extractors

Includes an efficient Friedrichs condenser An efficient extraction apparatus for general purpose use Consists of an extractor, a special Friedrichs condenser and a flask, all equipped with Standard Taper joints Condenser tubulation o.d. is 10 mm for 3/8 inch i.d. tubing

Extraction Apparatus
Chromalox

Extraction Apparatus

Thomas Cellulose...
Thomas®

Thomas Cellulose Extraction Thimbles

Wide selection of sizes Most Soxhlet extractor sizes Consistent wall thickness High-purity glass binderless microfiber Common Cellulose Thimble applications include fat determination of meat and dairy products, determination of PCB in fish products, determination of free fats in food products,…

Cellulose Extraction...
Ahlstrom

Cellulose Extraction Thimbles

Ahlstrom‘s high purity cellulose extraction thimbles are most commonly used in Soxhlet extraction units for the separation of individual components from a mixture of solids and semisolids by solvent extraction. The use of a Soxhlet extractor provides a safe method of extraction with toxic…

Soxhlet Extraction...
Wheaton

Soxhlet Extraction Apparatus Flasks

Flat-bottom flask for Soxhlet Extraction Apparatus 1/Case

Micro-Kjedahl...
Electrothermal (Bibby Scientific US)

Micro-Kjedahl Extraction Heaters

The Electrothermal Macro-Kjeldahl Extraction Heaters and Micro- Kjeldahl accept volume sizes from 80 to 800ml. Individual built-in controllers regulate quartz fibre heating elements up to 550o to 800o C. Macro Kjeldahl   Macro Kjeldahl Stainless-steel construction permits…

Extraction Apparatus
Electrothermal (Bibby Scientific US)

Extraction Apparatus

The Multi (Extraction) Mantle with three recesses has a built-in electronic controller and offers a choice of heater only (EME3) or heater/stirrer (EMEA3) combination. They may be used with the FM110 Flow Monitor. The vented case's unique air flow ensures the case remains "cool-to-the-touch".…

Thomas Glass...
Thomas®

Thomas Glass Microfiber Extraction Thimbles

Wide selection of sizes Most Soxhlet extractor sizes Consistent wall thickness High-purity glass binderless microfiber Common Glass Microfiber Thimble material applications include gravimetric methods for hot environments, gravimetric methods for acidic gasses, and extraction methods common to…

125 ml App, Soxhlet...
Wheaton

125 ml App, Soxhlet Extraction, Gnd

Use this apparatus for continuous extraction of analytes from a solid into an organic solvent. As the flask containing the solvent is heated, vapors rise in the larger outside tube, enter the water-cooled condenser, and liquate. When the liquid level in the extractor reaches the top of the bent…

App, Soxhlet...
Wheaton

App, Soxhlet Extraction, Micro, Thds

Use this apparatus for continuous extraction of analytes from a solid into an organic solvent. The Wheaton Connection eliminates the need for hooks, springs and clamps common to standard ground joint designs. As the flask containing the solvent is heated, vapors rise in the larger outside tube,…

Micro-Glass Fiber...
Munktell

Micro-Glass Fiber Thimbles, Grade ET/MG 160

Munktell’s high purity micro-glass fiber thimbles can be used in temperatures up to 500°C. They are particularly recommended for aggressive solvents and for analytical registration of environmental pollution.

Cellulose Extraction...
Munktell

Cellulose Extraction Thimbles, Grade ET/401

Perfect sample reservoirs for Soxhlet extraction in quality control, research and/or analysis. Solvent extraction from solids and semi-solids can be carried out easily and reliably. The thimbles are specially designed to fit Soxhlet extractors and automatic extractors. All Munktell…

15 X 60 MM THIMBLE
Wheaton

15 X 60 MM THIMBLE

High-Purity Glass...
GE Healthcare

High-Purity Glass Microfiber Thimbles

High-purity glass microfiber thimbles manufactured from 100% pure borosilicate glass are available for specialized applications. The thimbles are completely free of binders or additives and can be used at temperatures up to 500°C or when using solvents incompatible with cellulose thimbles. These…

PYREX Accelerated...
Corning

PYREX Accelerated One-Step Extractor/Concentrator

Modular PYREX Accelerated One-Step extractor-concentrator performs extraction, concentration, and drying with the same apparatus and is designed for use with solvents of heavier specific gravity than sample being extracted. ?Extraction and concentration can be done in 1/3 of the time. Pesticides…

Variable Speed...

Variable Speed Extraction Mixer Systems

Automatically control mixing of up to four 1 L or 2 L extraction vessels Dangerous pressure build-up is prevented with specially designed extraction vessels Entire assembly is designed to fit inside a standard fume hood Mixers provide controlled mixing as the vessels move back and…

Vacuum Manifold...
Agilent Technologies

Vacuum Manifold Accessories

Micro-Quartz Fiber...
Munktell

Micro-Quartz Fiber Thimbles, Grade ET/MK 360

Micro-Quartz fiber thimbles are specially developed for analysis of air pollution. The are made of binder-less quartz fiber material and temperature-resistant up to 900°C.

Extraction Thimbles
Sartorius

Extraction Thimbles

Cellulose thimbles are especially suited for all routine extractions. They are manufactured from cotton linters with a high alpha-cellulose content and are thermally stable up to 100°C.