General Chromatography

Page  2 3  of 3 | Next
Sort
View
Show
Agilent Choice...
Agilent Technologies

Agilent Choice Liners

Agilent’s engineering and testing efforts focus on these parameters when designing liners for Agilent inlet systems. Intensive liner development and testing have resulted in a set of liners that are recommended whenever new methods are being developed, when methods are being optimized, or when…

Universal/External...
Agilent Technologies

Universal/External Split Vent Trap

Split vent trap stops environmental pollution. The split vent trap lab environment from the contaminants released by split injection to 500 times the amount of sample reaching the detector into the replaceable, impregnated carbon filter media traps and eliminates contaminants. The traps are also…

Economy Indicating...
Agilent Technologies

Economy Indicating Refillable Moisture Traps

Agilent Indicating Moisture Traps are designed to remove water, oil, and organics from gases employed in, but not limited to, gas chromatography. Refillable moisture traps are constructed from Lexan brand polycarbonate tubing. Lightweight, chemically resistant and of superior strength when compared…

Integrators,...
Agilent Technologies

Integrators, Integrator Supplies And Cables

Cellulose Papers For...
GE Healthcare

Cellulose Papers For Chromatography, Whatman 3 MM Sheets

3MM-Chromatography Paper was developed specifically for requirements of electrophoresis as well as chromatography widely used in blotting procedures High-purity alpha cellulose has low ash content; no recycled materials are incorporated and there are no metallic contaminants, particularly iron…

Chromatography...
Munktell

Chromatography Papers

Made of pure cotton linters. Produced with an alphacellulose content of nearly 100%. Application hints: To obtain reproducible results, the fiber direction has to be taken into account The capillary rise is always higher in machine direction than in cross direction. The…

Liner O-Rings
Agilent Technologies

Liner O-Rings

Agilent fluorocarbon liner O-rings Liners are sealed in the inlet with O-rings or graphite seals Graphite seals are used when inlet temperatures exceed 350°C Fluorocarbon O-ring seals are easier to replace than graphite that deforms and flakes apart Pre-cleaned, then conditioned to eliminate…

Gas Cylinder...
Agilent Technologies

Gas Cylinder Regulators

Brass body, dual stainless steel diaphragms These regulators and Agilent’s broad spectrum of in-line filters, combination traps, and gas purification systems are an excellent combination to plumb your systems.

Tube Fittings, Male...
Swagelok

Tube Fittings, Male Connectors

Connect fractional tubing to female NPT thread

GC Installation Kits
Agilent Technologies

GC Installation Kits

Agilent Installation Kits for GC are designed to provide you with the essential items necessary for a successful installation while providing a substantial cost savings over individual purchases. GC Basic Installation Kit: Includes copper tubing, column nuts, two moisture traps, and five…

Tube Fittings,...
Swagelok

Tube Fittings, Female Connectors

Connect fractional tubing to male NPT thread 2713B01 to B27 are brass 2713B32 to B44 are stainless steel

Cellulose Papers For...
GE Healthcare

Cellulose Papers For Chromatography, Whatman 1 Sheets

3MM-Chromatography Paper was developed specifically for requirements of electrophoresis as well as chromatography widely used in blotting procedures High purity alpha cellulose has low ash content; no recycled materials are incorporated and there are no metallic contaminants, particularly…

Standard GC Inlet...
SGE

Standard GC Inlet Liners

High temperature deactivation Manufacturer’s guarantee to fit Economically priced All liners are manufactured to the original equipment tolerances and are deactivated using a proprietary high temperature gas phase deactivation to ensure inertness.

Tube Fittings, Nuts,...
Swagelok

Tube Fittings, Nuts, Knurled Nuts and Male Nuts

For fractional tubing Available in brass or stainless steel

Snoop
Agilent Technologies

Snoop

Leak test most pressurized gas systems. We recommend that leak detecting solutions be used with care where there is any possibility of the fluid being aspirated into gas flow streams supplying the column or detector. This squeezable bottle comes with a “Snooper Tube” extendable up to 12 inches (…

Ferrule Tools
Agilent Technologies

Ferrule Tools

Ferrule Tools Tools are designed to remove ferrules stuck inside fittings. Screw the stainless steel ferrule tool into the ferrule and pull it out. Use the smaller capillary ferrule tool for capillary column ferrules (0.32 mm ID column and smaller). The megabore ferrule tool is for megabore…

Hydrocarbon/Moisture...
Agilent Technologies

Hydrocarbon/Moisture Traps

Adsorbent refiles for hydrocarbon/moisture traps allow continued removal of extremely low levels of both moisture and hydrocarbons. Refill supplies material for two recharges for HMT trap.

Big Hydrocarbon...
Agilent Technologies

Big Hydrocarbon Traps

Capacity: 80 grams of medium to heavy molecular weight hydrocarbons Pressure: Up to 250 psig Efficiency: reduction of C4 hydrocarbons to less than 15 ppb 750 cubic centimeter gas purifiers Ideal for bulk purification applications or where several instruments are plumbed from a…

Standard GC Inlet...
SGE

Standard GC Inlet Liners

PERKIN ELMER INLET LINERS - For Perkin Elmer Autosystem, 6.2 mm O.D. 92 mm Length High temperature deactivation Manufacturer’s guarantee to fit Economically priced All liners are manufactured to the original equipment tolerances and are deactivated using a proprietary high…

Big Moisture Traps
Agilent Technologies

Big Moisture Traps

Ultra-high capacity for moisture Capacity 130 g H2O Pressure up to 250 psig Reduce H2O to ≤5 ppb 750 cc gas purifiers Refillable Suitable for bulk purification applications or where several instruments are plumbed from a single gas source.

Molecular Sieve 13X...
Agilent Technologies

Molecular Sieve 13X and Indicating 4

Available in three different sizes Mixed packing bed prevents improper installation Easily refillable Tested to 150 psi (helium) Both inlet and outlet connectors are equipped with stainless steel frits to prevent particulates from entering the gas stream. Indicating 4Å is the…

GC Column Baskets &...
Agilent Technologies

GC Column Baskets & Hangers

Baskets and hangers are for use with gas chromatography columns

Nuts
Agilent Technologies

Nuts

Standard GC Inlet...
SGE

Standard GC Inlet Liners

VARIAN INLET LINERS - For Varian Injector Models 1075/1077, 6.3 mm O.D. x 72 mm Length High temperature deactivation Manufacturer’s guarantee to fit Economically priced All liners are manufactured to the original equipment tolerances and are deactivated using a proprietary…

Economy Non...
Agilent Technologies

Economy Non-Indicating Oxygen Traps

Bubble Flowmeter...
Agilent Technologies

Bubble Flowmeter Accessories And Replacement Parts

Hydrocarbon Traps
Agilent Technologies

Hydrocarbon Traps

Remove organics from carrier gases, air and hydrogen High capacity 200 cc of filtering media Impregnated carbon filter media Refill includes media for two recharges of HT200 Series Hydrocarbon Trap

Focus Liners
Agilent Technologies

Focus Liners

Improved reproducibility Precise amount of glass wool in the ideal position traps non-volatile sample residue Glass wool provides extra surface area for vaporization, traps nonvolatile sample residue, and wipes any residual sample from the needle.

Standard GC Inlet...
SGE

Standard GC Inlet Liners

SHIMADZU INLET LINERS - For Shimadzu 17A (SPL-17 Injector), 5 mm O.D. x 95 mm Length High temperature deactivation Manufacturer’s guarantee to fit Economically priced All liners are manufactured to the original equipment tolerances and are deactivated using a proprietary high…

Focusliner GC Inlet...
SGE

Focusliner GC Inlet Liners

VARIAN INLET LINERS - For Varian Injector Models 1075/1077, 6.3 mm O.D. x 72 mm Length Precision placement of quartz wool improves reproducibility Manufacturer’s guarantee to fit Simple to install High temperature deactivation Quartz wool is secured by means of a tapering above and…

Tube Fittings, Low...
Swagelok

Tube Fittings, Low Dead Volume Unions and Union Tee

Available in brass or stainless steel

Capillary Column...
Agilent Technologies

Capillary Column Rinse Kit

Solvent rinsing removes many contaminants that accumulate in columns. The contaminants are removed by passing solvents through the column. Only bonded and cross-linked phase columns should be rinsed, or permanent damage to the column will result.