NARROW RESULTS BY

Manufacturer

Category

Page  of 1
Sort
View
Show
CT-500 And CT-518...
Cannon Instrument

CT-500 And CT-518 Constant Temperature Baths

…depth: 457 mm (18") Cylindrical glass vessel is deeper than glass vessel of CT-500, allowing the use of longer viscometers such as the Cannon- Ubbelohde Four-Bulb Shear Dilution Viscometer (ten-fold dilution type). Otherwise identical to Model CT-500. Power requirements: 9726A17 is 115 to 120 V, 50/60…

SimpleVIS™ Portable...
Cannon Instrument

SimpleVIS™ Portable Viscometer

kinematic viscosity, no need to correlate data Modified cross-arm style tube, works with both transparent and opaque oils Reliable, only 2 moving parts Easy-to-use graphical touch screen Small sample volume: <0.5 mL Rapid automated analysis: <3 minutes The Cannon SimpleVIS™ Portable Viscometer

BS/IP/SL Suspended...
Cannon Instrument

BS/IP/SL Suspended Level Viscometer

Calibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105 Precision: ?0.2% Minimum sample volume: 11 mL. Requires liquid bath depth of 250 mm (10”). Includes certificate…

Semi-Micro, Cannon...
Cannon Instrument

Semi-Micro, Cannon CUSMC Series Viscometer

Calibrated For measurement of kinematic viscosity of small samples of transparent Newtonian liquids Meets ASTM Standard D 445; specifications conform with ASTM Standard D 446 Viscometer constant is same at all temperatures Initial sample can be diluted to as much as 20 mL for intrinsic viscosity…

Cannon-Ubbelohde,...
Cannon Instrument

Cannon-Ubbelohde, CUU And CUC Series Viscometers

Uncalibrated and Calibrated Viscometers Suspended level viscometer for measurement of kinematic viscosity of transparent Newtonian liquids Also used for evaluating jet fuels and hydraulic fluids Meets ASTM D 445 and D 446, as well as ISO 3104 and 3105 requirements Suitable for use at temperatures…

Cannon-Ubbelohde UBU...
Cannon Instrument

Cannon-Ubbelohde UBU And UBC Series

Uncalibrated and Calibrated Viscometers Measure kinematic viscosity of transparent Newtonian liquids by suspended level principle Meets ASTM D 445 and D 446 and ISO 3104 and 3105 requirements. Precision: ?0.2% Similar to Cannon-Ubbelohde but less rugged in design. Includes instruction…

Cannon-Fenske Series...
Cannon Instrument

Cannon-Fenske Series Viscometers

…outside of the box and on the viscometer. Additional sizes are available on special order. Holder not supplied. See Thomas numbers 9726M50 and M53 for holders. Cannon Fenske Opaque, CFOU (Uncalibrated) and CFOC (Calibrated) Viscometers Reverse-Flow Type; Measures kinematic viscosity of dark Newtonian…

TE-3000 Constant ...
Cannon Instrument

TE-3000 Constant (Low) Temperature Bath

For glass capillary viscometers and other instruments requiring precise low temperature control All-digital, LCD displayed, microprocessor-controlled temperature regulation; Cooled thermoelectrically (solid state heat pump) Temperature range: -30°C to +30°C °C/°F selectable operation…

BS/IP/SL(S)...
Cannon Instrument

BS/IP/SL(S) Viscometers

Calibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision: ±0.2%. Minimum sample volume:10 mL. Requires liquid bath depth of 230 mm (9”). Includes certificate of calibration…

Viscometer Cleaning...
Koehler

Viscometer Cleaning And Drying Apparatus

Removes all traces of oil Air pressure drives solvent No electrical contact needed Unit is designed to wash the inside of glass kinematic viscometer tubes with a jet of solvent. At the touch of a button, the solvent stream is cut off and an air jet is directed into the tubes for drying. Cleaning…

Zeitfuchs Cross-Arm...
Cannon Instrument

Zeitfuchs Cross-Arm Calibrated Viscometers

…boxed. Serial number is printed on the outside of the box and on the viscometer. Certificate of calibration and instruction sheet provided. Holders not included; see Thomas numbers 9726M95 and M98. For measurement of kinematic viscosity of transparent and opaque Newtonian liquids Meets ASTM Standard…

Zeitfuchs Cross-Arm...
Cannon Instrument

Zeitfuchs Cross-Arm Unity Factor, Found Holder, ZCAXC-RO Series Viscometers

Calibrated viscometers For measurement of kinematic viscosity of transparent and opaque Newtonian liquids Meets ASTM Standard D 445; specifications conform with ASTM Standard D 446 Also used to measure kinematic viscosity of cut-back asphalts and road oils at 140°F and asphalt cements…

BS/IP/RF U-Tube...
Cannon Instrument

BS/IP/RF U-Tube Reversed Flow Viscometers

Calibrated viscometers For measuring kinematic viscosity of opaque Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision: ?0.3%. Minimum sample volume: 7 mL. Requires liquid bath depth of 280 mm (11"). Includes certificate of calibration…

Cannon-Manning Semi...
Cannon Instrument

Cannon-Manning Semi-Micro, Cannon CMSMC Series Viscometers

Calibrated Viscometers For measurement of kinematic viscosity of small samples of transparent Newtonian liquids, particularly petroleum products or lubricants Meets ASTM D 445 requirements Precision: ?0.2% Specifications conform with ASTM Standard D 446. Minimum sample volume: 1…

BS/U Tube...
Cannon Instrument

BS/U Tube Viscometers

Calibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision: ±0.2%. Minimum sample volume: 7 mL in sizes A to C; 12 mL in sizes D to F ; 23 mL in sizes G and H. Requires liquid…

BS/IP/MSL Miniature...
Cannon Instrument

BS/IP/MSL Miniature Suspended Level Viscometers

Calibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Specifications conform to ASTM D 446 and ISO 3105. Precision:±0.2%. Minimum sample volume:4 mL. Requires liquid bath of 305 mm (12”). Includes certificate of calibration and…

Bubble Viscometers
BYK-Gardner

Bubble Viscometers

Yields accurate kinematic viscosity data quickly and easily using the Alphabetical Comparison Method (upward speed of a trapped air bubble) Conforms to ASTM D 1131, D 1545 and D 1725 Standard tubes easily identified by large letters Quick and easy cleaning Viscosity of the liquid sealed in each…

VISDISK for Windows
Cannon Instrument

VISDISK for Windows

…Chart Blending Method Kinematic viscosity calculations- allows the estimation of kinematic viscosity (cSt), viscosity (cP) and density of an oil at any temperature Determination of Viscosity Index- calculates the Viscosity Index after entering the kinematic viscosity at any two temperatures…

BS/U/M Miniature U...
Cannon Instrument

BS/U/M Miniature U-Tube

Calibrated viscometers For measuring kinematic viscosity of transparent Newtonian liquids Meets ASTM D 445 and ISO 3104 Precision: ±0.2% Specifications conform to ASTM D 446 and ISO 3105. Minimum sample volume: 2 mL. Requires liquid bath depth of 230 mm (9"). Includes certificate of calibration…

CT-1000 Constant...
Cannon Instrument

CT-1000 Constant Temperature Baths

…holes 51 mm (2") in diameter for insertion of viscometers. Each unit maintains accurate temperature control of 0.01°C within the range of 20°C to 100°C and 0.03°C above 100°C, providing the temperature sensitivity required by ASTM D 445 for kinematic viscosity measurements. Two electric heating elements…

Certified Viscosity ...
Cannon Instrument

Certified Viscosity “Check Oils” for SAE Target Viscosities

…) and 3.8 L (1 Gallon) sizes. The oils enable users to “check” the performance of their Cold-Cranking Simulator, Mini-Rotary Viscometer, and Kinematic Viscometers by measuring commercially-available formulated engine oils. Viscosity values for the check oils will be at typical blend targets. Custom…

CT-600 Constant...
Cannon Instrument

CT-600 Constant Temperature Bath

Ideal for kinematic viscosity determinations between 10°C and 30°C Built-in thermoelectric cooling provides “rock-solid” temperature control at ambient and below Meets ASTM D 445 precision specifications from 10°C to 100°C The Cannon CT-600 has many of the engineering and control features…

Ink and Paint...
Cannon Instrument

Ink and Paint Viscosity Standards

For ink and paint viscometers For use with Zahn, Shell and Ford viscometer cups. Based on NIST value of 1.0016 centipoise for water at 20°C. Traceable to NIST. Approximate kinematic viscosity and drain times for the various cups at 25°C are given in table. Actual values are furnished with each standard…